Data Centre Fire Services

Complete Fire Protection for Mission Critical Data Centres

Inert gas fire suppression cylinder banks installed by DIS Fire

Data centres run around the clock, and a fire, a false alarm or an unplanned discharge can all take critical load offline. DIS Fire delivers complete fire protection for hyperscale and colocation facilities, covering active, wet and passive systems under one accountable contractor. Our scope spans fire detection and alarm, aspirating smoke detection, emergency warning, gaseous and water mist suppression, sprinkler and pre action systems, fire hydrants, pumps and water storage tanks, passive fire protection, portable fire equipment, and the testing and maintenance that keep every system compliant for the life of the building. We take responsibility for the fire side of every interface with mechanical, electrical, security and BMS systems, and deliver the models, documentation and commissioning evidence that data centre owners expect.

Built for Uptime

Why DIS Fire for Data Centres

One accountable contractor for active, wet and passive fire protection, from design to lifecycle maintenance.

One Accountable Contractor

Active, wet and passive fire protection delivered under a single contract, removing the gaps and interface risk between separate fire trades.

BIM to LOD 500

Native Revit models progressed from issued for construction through to field verified as installed records, integrated into the builder’s federated model.

Commissioning Discipline

Structured inspection and test plans, cause and effect verification and integrated systems testing, built on our experience commissioning large energy facilities.

Battery Risk Expertise

The same engineering team behind our battery energy storage work applies its lithium ion fire risk knowledge to UPS and battery rooms.

Start the Conversation

Talk to Us About Your Fire Safety Needs

Speak with our experts today and get a fire safety solution designed to protect your people and property.

How We Deliver

From Design to Handover

A staged delivery model aligned with data centre construction programmes and Independent Commissioning Agent requirements.

Fire Safety Strategy and Design

Early input to the fire engineering brief and performance solutions, followed by design delivered at 30, 80 and 100 percent stages, with approvals managed through the fire brigade, building surveyor and fire engineer.

Coordinated Installation

Wet, dry and passive services modelled in Revit and coordinated in the federated model before installation, reducing clashes and rework on site.

Cause and Effect Programming

Fire matrix logic developed and verified for every interface, from HVAC shutdown and smoke control to access control release, suppression release and pre action valve operation.

Integrated Systems Testing

Commissioning delivered through Levels 1 to 5, witnessed by the Independent Commissioning Agent, including hydrant and sprinkler flow tests, pump performance tests and full integrated systems testing.

Lifecycle Maintenance

Routine inspection, testing and maintenance of every fire safety measure to AS 1851 after handover, protecting uptime and compliance.

Partner with the Experts

Let’s Build a Safer, Smarter Fire Protection System

From system design to full compliance testing, our team helps you achieve the highest standards of fire safety and performance.

Technical Scope

Systems We Deliver

Designed in accordance with the National Construction Code, AS 1670.1, AS 1670.4, AS 2118.1, AS 2419.1, AS 2941, AS 4214 and NFPA 75, and maintained to AS 1851.

Detection and Alarm

Addressable networked fire indicator panels, aspirating smoke detection in data halls and critical rooms, point and linear heat detection, triple IR flame detection for generator enclosures, and lithium ion battery off gas monitoring for UPS and battery rooms.

Emergency Warning

Emergency warning and intercommunication systems with speakers, visual alarm devices and evacuation zoning designed around the facility’s emergency plan.

Gaseous and Water Mist Suppression

Inert gas and fluoroketone clean agent systems for critical rooms, high pressure water mist, pressure relief dampers and room integrity testing.

Sprinkler and Pre Action Systems

Wet pipe sprinklers for support areas and double interlock pre action systems for data halls, minimising the risk of accidental water release over IT equipment.

Hydrants, Hose Reels, Pumps and Tanks

Fire hydrant ring mains, booster assemblies, hose reels, diesel and electric fire pumpsets, and fire water storage tanks sized for the site’s hydraulic demand.

Passive Fire Protection

Fire stopping of service penetrations, fire rated walls and ceilings, fire doors, fire and smoke dampers, and cable and structural fire protection, all tested systems with full penetration registers.

Portable Fire Equipment

Fire extinguishers and fire blankets selected for each hazard, including electrical and battery risks.