Fire Detection and Alarm

Networked Fire Detection for Complex Facilities

Addressable fire detection and alarm systems are the backbone of any building’s fire safety strategy. DIS Fire designs and delivers networked systems that identify a fire at the exact device location, coordinate the building’s response and give operators clear information when it matters most. From a single switchroom to a multi building campus, we handle design, supply, installation, programming and commissioning.

Reliable Early Warning

Why Addressable Detection

Accurate detection and clear information for faster, safer decisions.

Precise Alarm Location

Individual device addressing shows exactly where an alarm or fault originates, speeding up response.

Fewer False Alarms

Multi sensor detectors and careful device selection reduce nuisance alarms in demanding environments.

Scalable Networks

Systems grow with the site, from a single building to a networked campus.

Start the Conversation

Talk to Us About Your Fire Safety Needs

Speak with our experts today and get a fire safety solution designed to protect your people and property.

Intelligent Detection

How It Works

Detectors report to networked panels that run the agreed cause and effect logic for the building.

Addressable Loops

Each detector and module reports individually to the panel, so alarms are located precisely and faults are found quickly.

Networked Panels

Multiple fire indicator panels share information across a site, giving a single view of the whole campus.

Cause and Effect Logic

Programmed outputs control HVAC, doors, lifts, suppression release and warning systems according to the approved fire matrix.

Partner with the Experts

Let’s Build a Safer, Smarter Fire Protection System

From system design to full compliance testing, our team helps you achieve the highest standards of fire safety and performance.

Scope and Standards

Technical Specifications

Designed in accordance with AS 1670.1 and AS 4428, and maintained to AS 1851.

Panels

Addressable fire indicator panels, sub panels and mimic panels, networked across buildings where required.

Field Devices

Smoke, heat and multi sensor detectors, manual call points, input and output modules, and hazardous area devices.

Monitoring

Alarm signalling equipment connected to the fire brigade, with integration to BMS and security systems.

Frequently Asked Questions

Fire Detection FAQs

Common questions about addressable detection, networking and maintenance.

No items found.